Dragging building-condition reports into the 21st century
Building owners and accountable persons are expected to maintain reliable information, understand the risks their buildings present and demonstrate how those risks are being managed, also known as the ‘golden thread’.
Yet there is a practical problem software can’t solve: the quality of the information.
A digital record is more organised, searchable and available. It can be both more accessible and more protected than its printed equivalent and it’s easier to update and edit. But there’s a good chance that it still describes a building as it was three years ago, with no certainty of who read it.
If the external envelope has developed defects since the last survey, the system might paint a rose-tinted picture that all is well. In reality, that document is hiding the true condition and risk from the dutyholder, the one whose professional and personal reputation is on the line.
The problem isn’t whether a PDF belongs in the golden thread; it’s whether the evidence behind the record is current, consistent, specific and trustworthy.
From records to live evidence
Condition surveys have an important role in planned maintenance and capital expenditure. They establish a baseline, help prioritise investments and identify defects requiring attention. The problem arises when that baseline is treated as a definitive line in the sand, rather than a record of conditions at a particular time. It must be treated as a chapter, not the entire story.
An external wall or roof is exposed to weather, water ingress, deterioration and the effects of previous repairs. A finding recorded in 2023 might have been resolved, worsened or become irrelevant following subsequent work. Without a clear inspection history, it’s difficult to decide what to do.
The Building Safety Regulator’s golden thread guidance (gov.uk/guidance/keeping-information-about-a-higher-risk-building-the-golden-thread) requires relevant building information to be managed digitally, kept up-to-date and made accessible in a way that people can use. For higher-risk residential buildings in England, that information supports the dutyholder’s ability to assess and manage the building safety risks.
It’s therefore more than just record keeping; it’s how those records are managed and how evidence is gathered, grouped, risk-rated and acted on.
A useful system should show what was inspected, when it was inspected, what was found, what remains uncertain and what action followed. An old report can still be valuable but its date and limitations remain, and it shouldn’t become the assumed current condition of the building.
Specify the inspection, not just the flight
Commissioning a building inspection, by drone or by a team using ladders and cherry pickers, should begin with the decisions the client needs to make, rather than the number of images required. It should define the assets in scope, the areas requiring inspection and any access restrictions. In short, it should be a meaningful exercise with agreed, tangible outputs, not one that ticks a box.
Coverage matters because thousands of images don’t correlate to a complete inspection. The client should be able to establish which roof section, parapet or ledge was inspected, which were inaccessible and why. Any gaps should be recorded explicitly rather than disappearing behind a general statement that the building was surveyed.
Visual and thermal capture can complement each other. High-resolution visual imagery can reveal cracking, displaced components, failed sealants, staining and other visible defects. Thermal imagery can identify surface-temperature patterns that might warrant further investigation, including anomalies potentially associated with moisture or insulation performance. Neither should be specified as a substitute for the other.
The deliverable should include more than photographs and a narrative report. Each finding needs a unique reference, a precise location, supporting imagery, a description of the observed condition, a consistent grading methodology and a recommended next action. That’s what the golden thread should be.
Location should be meaningful to the people managing the asset, and a marked-up image or drawing should enable the defect to be found again, both by the current team and by a future employee because accessibility is as important as the record itself.
Finally, the specification should require competent human review of the findings, with the reviewer accountable for the conclusions presented. Automated image analysis can help identify potential defects, but detection isn’t the same as diagnosis. The output needs to distinguish between an observed defect, a suspected problem and a confirmed underlying cause, hence qualified surveyors and facade engineers still having an integral part to play.
Avoiding false positives
If a harmless feature is recorded as a significant defect, it can trigger unnecessary investigations, divert limited budgets and undermine confidence in the wider inspection process.
At portfolio scale, even a modest rate of misclassification, such as a loose twig thought to be a loose electrical wire or a line of organic debris thought to be a structural crack, can create substantial ‘noise’.
Thermal anomalies can also have several possible explanations. Treating every automated alert as a confirmed defect risks turning a safety case into a collection of untested assumptions and unfounded conclusions that, say, the whole roof is a disaster.
A defined verification process
Potential findings should be reviewed against the original imagery, surrounding building details and relevant historic records. If the evidence is inconclusive, the finding should say so. A reviewer should be able to reject an alert, downgrade it or request further investigation, with the reasoning retained in the record in order to make the decision defensible.
Grading needs the same discipline. A condition rating should follow an agreed methodology, with clear definitions and evidence supporting the assigned grade. It shouldn’t imply a structural or fire-safety conclusion that the inspection method can’t establish. It’s worth remembering that in spite of thermal and LiDAR capabilities, no camera can see through walls.
Where a finding could affect life safety, the next action should reflect that potential consequence and the need for competent assessment, rather than relying only on an image-based score.
What thermal imagery can’t tell you
Thermal imaging is useful but it has limitations. It measures surface temperatures and displays patterns in infrared radiation; what it doesn’t do is directly measure moisture content, establish the composition of a wall or confirm that insulation is missing. Thermal results can be affected by weather, solar exposure, emissivity, reflections, internal heating and the time elapsed since a surface was exposed to changing conditions. A thermal anomaly is therefore a reason to investigate, not proof of a defect or its cause.
The same distinction applies to fire safety. UAV imagery can document visible features and help to identify areas requiring closer attention but it can’t establish the full build-up of an external wall, verify concealed cavity barriers or determine the fire performance of unknown materials. A fire-risk appraisal of external walls (FRAEW) must be undertaken by a suitably competent specialist using the relevant methodology. The government’s FRAEW guidance (gov.uk/government/publications/fire-risk-appraisals-of-external-walls-fraews) and PAS 9980:2026 set out the appropriate framework for assessing the fire risk of external walls.
The same applies to structural integrity, concealed water ingress and the condition of hidden fixings. A good UAV survey identifies the limits of its evidence and makes the hand-over to the dutyholder explicit.
Usable evidence
The final test is what happens after the report has been delivered. If the only output is a PDF saved against a property record, the dutyholder might still have to search through pages of photographs to understand the current position or answer a regulator’s question.
The findings should be transferred into the relevant golden thread or asset management system as structured, individually-traceable records. Each should retain its location, inspection date, evidence, grade, limitations, recommended action, responsible person and status.
Links to the original report and source imagery preserve the audit trail, while version control makes it possible to see what changed and when, and by whom.
Crucially, the record should follow the defect through to resolution. It should complement everything from capex forecasts to reducing working at height, and from planned preventative maintenance programmes to the lives of those living in the buildings.
Ruari Woodward is a director at Ovrsite.